IMR OpenIR
Effect of HCl on the corrosion and wear of in-bed tubes in a laboratory simulated bubbling fluidized bed
Hou, PY; Niu, Y; Sum, TJ; Stringer, J
Corresponding AuthorHou, PY()
1999-12-01
Source PublicationWEAR
ISSN0043-1648
Volume233Pages:635-646
AbstractHeat-exchanger tubes in fluidized bed combustors (FBCs) often suffer material loss due to combined corrosion and erosion. The effect of chlorine on in-bed tube wastage and its possible mechanism are being studied using the EPRI/LBNL FBC wastage simulator. This test rig was designed to simulate dense particle impacts on tube bottoms with well-controlled parameters, and has been proven to closely reflect situations found in operating bubbling FBCs, In this study, HCl gas was chosen to be the Cl source and was introduced into the fluidizing air with a 50-ppm concentration. Tests were performed at temperatures ranging from ambient to 400 degrees C using 1018 low carbon steel rods in a bed of commercial SiO(2) sand that had an average size of 800 mu m. The wear profile after each test was measured using a profilometer. Results showed an increase in material wastage rates in the presence of HCl, and that the rate was significantly higher with higher test temperatures. Microstructural and chemical analysis of the wear surface and corrosion products are reported. It is concluded that the dominating effect of HCl on the wastage rates is due to an enhanced oxidation and a reduced scale adherence. (C) 1999 Elsevier Science S.A. AU rights reserved.
Keywordcorrosion wear in-bed tube
Indexed BySCI
Language英语
WOS Research AreaEngineering ; Materials Science
WOS SubjectEngineering, Mechanical ; Materials Science, Multidisciplinary
WOS IDWOS:000084590500070
PublisherELSEVIER SCIENCE SA
Citation statistics
Cited Times:8[WOS]   [WOS Record]     [Related Records in WOS]
Document Type期刊论文
Identifierhttp://ir.imr.ac.cn/handle/321006/109048
Collection中国科学院金属研究所
Corresponding AuthorHou, PY
Affiliation1.Lawrence Berkeley Natl Lab, Div Mat Sci, Berkeley, CA 94720 USA
2.Chinese Acad Sci, Inst Corros & Protect Met, Shenyang, Peoples R China
3.Elect Power Res Inst, Palo Alto, CA 94304 USA
Recommended Citation
GB/T 7714
Hou, PY,Niu, Y,Sum, TJ,et al. Effect of HCl on the corrosion and wear of in-bed tubes in a laboratory simulated bubbling fluidized bed[J]. WEAR,1999,233:635-646.
APA Hou, PY,Niu, Y,Sum, TJ,&Stringer, J.(1999).Effect of HCl on the corrosion and wear of in-bed tubes in a laboratory simulated bubbling fluidized bed.WEAR,233,635-646.
MLA Hou, PY,et al."Effect of HCl on the corrosion and wear of in-bed tubes in a laboratory simulated bubbling fluidized bed".WEAR 233(1999):635-646.
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Hou, PY]'s Articles
[Niu, Y]'s Articles
[Sum, TJ]'s Articles
Baidu academic
Similar articles in Baidu academic
[Hou, PY]'s Articles
[Niu, Y]'s Articles
[Sum, TJ]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Hou, PY]'s Articles
[Niu, Y]'s Articles
[Sum, TJ]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.