X80 Steel Corrosion Induced by Alternating Current in Water-Saturated Acidic Soil | |
Wei, Boxin1,2; Qin, Qingyu1,2; Fu, Qi1,2; Bai, Yunlong1; Xu, Jin1; Yu, Changkun1; Sun, Cheng1; Ke, Wei1 | |
Corresponding Author | Xu, Jin(xujin@imr.ac.cn) ; Sun, Cheng(chengsun@imr.ac.cn) |
2020-03-01 | |
Source Publication | CORROSION
![]() |
ISSN | 0010-9312 |
Volume | 76Issue:3Pages:248-267 |
Abstract | X80 steel corrosion induced by alternating current (AC) had been investigated by surface analyses and electrochemical measurements in water-saturated acidic soils. The AC sharply increased the corrosion rate of X80 steel. Moreover, the DC potential of X80 steel shifted toward the negative direction after applying AC density, and decreased with the AC density ascending from 0 A/m(2) to 200 A/m(2). A power function model, CR = ai(n) + b, was used to reflect the relation between AC density and corrosion rate. gamma-FeOOH acting as an oxidizer weakened the protective ability of product film, and further accelerated the corrosion of steel. |
Keyword | AC-induced corrosion acidic soil X80 pipeline steel gamma-FeOOH |
Funding Organization | National Natural Science Foundation of China |
DOI | 10.5006/3418 |
Indexed By | SCI |
Language | 英语 |
Funding Project | National Natural Science Foundation of China[51771213] ; National Natural Science Foundation of China[51871228] ; National Natural Science Foundation of China[51471176] |
WOS Research Area | Materials Science ; Metallurgy & Metallurgical Engineering |
WOS Subject | Materials Science, Multidisciplinary ; Metallurgy & Metallurgical Engineering |
WOS ID | WOS:000518605200002 |
Publisher | NATL ASSOC CORROSION ENG |
Citation statistics | |
Document Type | 期刊论文 |
Identifier | http://ir.imr.ac.cn/handle/321006/137647 |
Collection | 中国科学院金属研究所 |
Corresponding Author | Xu, Jin; Sun, Cheng |
Affiliation | 1.Chinese Acad Sci, Inst Met Res, Liaoning Shenyang Soil & Atmosphere Mat Corros, Natl Observat & Res Stn, Shenyang 110016, Peoples R China 2.Univ Sci & Technol China, Sch Mat Sci & Engn, Shenyang 110016, Peoples R China |
Recommended Citation GB/T 7714 | Wei, Boxin,Qin, Qingyu,Fu, Qi,et al. X80 Steel Corrosion Induced by Alternating Current in Water-Saturated Acidic Soil[J]. CORROSION,2020,76(3):248-267. |
APA | Wei, Boxin.,Qin, Qingyu.,Fu, Qi.,Bai, Yunlong.,Xu, Jin.,...&Ke, Wei.(2020).X80 Steel Corrosion Induced by Alternating Current in Water-Saturated Acidic Soil.CORROSION,76(3),248-267. |
MLA | Wei, Boxin,et al."X80 Steel Corrosion Induced by Alternating Current in Water-Saturated Acidic Soil".CORROSION 76.3(2020):248-267. |
Files in This Item: | There are no files associated with this item. |
Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.
Edit Comment