Initial experience of occluding special type patent ductus arterioses using the Amplatzer vascular plug
其他题名Initial experience of occluding special type patent ductus arterioses using the Amplatzer vascular plug
Zhang Po; Zhu Xianyang; Wang Qiguang; Zhang Duanzhen; Han Xiumin
2013
发表期刊CHINESE MEDICAL JOURNAL
ISSN0366-6999
卷号126期号:18页码:3456-3459
摘要Background Occluders licensed for clinical use are not fit for some special Krichenko E patent ductus arterioses. The Amplatzer vascular plug I (AVP1) has not been licensed for use for closure of patent ductus arteriose. We report our initial experience to occluding special type patent ductus arterioses with the AVP1 a single lobe device of single layer Nitinol mesh for short vessel landing zones.
其他摘要Background Occluders licensed for clinical use are not fit for some special Krichenko E patent ductus arterioses. The Amplatzer vascular plug I (AVP1) has not been licensed for use for closure of patent ductus arteriose. We report our initial experience to occluding special type patent ductus arterioses with the AVP1–a single lobe device of single layer Nitinol mesh for short vessel landing zones. Methods Patients referred with small and long Krichenko E patent ductus arterioses 1 mm to 3 mm in diameter underwent occlusion using AVP1. All cases underwent pre-, intra- and post-procedural echocardiography and chest X-ray at the completion of the procedure, the next day and at a 30-day, 3-month and 6-month follow-up visits. Device sizing for device waist diameter and length was based on aortography. Results From April 2008 to June 2012, 26 patients with a mean age of (7.6±8.0) years (range 6 months–32 years) and a mean weight of (23.8±14.8) kg (range 7–67 kg) underwent successful patent ductus arteriose closure. The mean ductus diameter was (2.1±0.7) mm (range 1–3 mm). Transpulmonary (22/26) and transaortic approaches (4/26) were used. No persistent patency was observed after 24 hours and after one month. No device displacement, residual flow and iatrogenic coarctation of the aorta were observed after three months and six months. Conclusions The AVP1 makes it easy to close some Krichenko E patent ductus arterioses. Smaller delivery catheter profile and symmetric cylindrical device shape allow for use for small and long Krichenko E patent ductus arterioses 1 mm to 3 mm in diameter and small patients through transaortic approaches. Broader experience is required to further delineate device and patient selection as well as to document its long-term efficacy and safety.
关键词TRANSCATHETER CLOSURE OCCLUSION COILS EMBOLIZATION DEVICE patent ductus arteriosus heart catheterization intervention studies therapeutic occlusion Amplatzer vascular plug I
收录类别CSCD
语种英语
CSCD记录号CSCD:4928328
引用统计
文献类型期刊论文
条目标识符http://ir.imr.ac.cn/handle/321006/143401
专题中国科学院金属研究所
作者单位中国科学院金属研究所
推荐引用方式
GB/T 7714
Zhang Po,Zhu Xianyang,Wang Qiguang,et al. Initial experience of occluding special type patent ductus arterioses using the Amplatzer vascular plug[J]. CHINESE MEDICAL JOURNAL,2013,126(18):3456-3459.
APA Zhang Po,Zhu Xianyang,Wang Qiguang,Zhang Duanzhen,&Han Xiumin.(2013).Initial experience of occluding special type patent ductus arterioses using the Amplatzer vascular plug.CHINESE MEDICAL JOURNAL,126(18),3456-3459.
MLA Zhang Po,et al."Initial experience of occluding special type patent ductus arterioses using the Amplatzer vascular plug".CHINESE MEDICAL JOURNAL 126.18(2013):3456-3459.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Zhang Po]的文章
[Zhu Xianyang]的文章
[Wang Qiguang]的文章
百度学术
百度学术中相似的文章
[Zhang Po]的文章
[Zhu Xianyang]的文章
[Wang Qiguang]的文章
必应学术
必应学术中相似的文章
[Zhang Po]的文章
[Zhu Xianyang]的文章
[Wang Qiguang]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。