IMR OpenIR
Preparation of Ordered Mesoporous Carbon/Polyaniline Electrodes and as Electrochemical Sensors for Cu2+
其他题名Preparation of Ordered Mesoporous Carbon/Polyaniline Electrodes and as Electrochemical Sensors for Cu2+
Guo Zhuo; Guo Tong; Zhao ChangLi; Gao YunPeng; Li Sha
2010
发表期刊CHINESE JOURNAL OF INORGANIC CHEMISTRY
ISSN1001-4861
卷号26期号:11页码:1927-1933
摘要A new electrode, obtained by the dispersion of ordered mesoporous carbon (MC) nanoparticles onto polyaniline (PANI) was presented in this paper. Ordered mesoporous carbon was prepared by pyrolysis of sucrose filled in the mesoporous channels of SBA-15 at 1 200 degrees C, and followed by dissolution of the silica matrix in hydrofluoric acid. The pore structure of the MC material, was evaluated using XRD, nitrogen adsorption, TEM. SEM showed that PANI-MC films presented a wholy modified morphology when compared to PANI film. Electrochemical characterization indicated that the potential shift toward negative direction. This can be attributed to the porous feature of MC, which imposes resistance for ion migration in mesoporous. The deposition potential and time had been optimized for determination of Cu2+ in aqueous solution. ASV analysis revealed that the new electrode presented a linear response to low concentrations of Cu2+. Under optimized conditions, the current showed a linear dependence with concentration in the range 1.00x10(-8)similar to 1x10(-6) mol . L-1. The detection limit was 6x10(-9) mol . L-1. The results showed good reproducibility and stability.
其他摘要A new electrode, obtained by the dispersion of ordered mesoporous carbon(MC) nanoparticles onto polyaniline(PANI) was presented in this paper. Ordered mesoporous carbon was prepared by pyrolysis of sucrose filled in the mesoporous channels of SBA-15 at 1 200 ℃, and followed by dissolution of the silica matrix in hydrofluoric acid. The pore structure of the MC material was evaluated using XRD, nitrogen adsorption,TEM.SEM showed that PANI-MC films presented a wholy modified morphology when compared to PANI film. Electrochemical characterization indicated that the potential shift toward negative direction. This can be attributed to the porous feature of MC, which imposes resistance for ion migration in mesoporous. The deposition potential and time had been optimized for determination of Cu2+ in aqueous solution. ASV analysis revealed that the new electrode presented a linear response to low concentrations of Cu2+. Under optimized conditions, the current showed a linear dependence with concentration in the range 1.00 ×10-81×10-6 mol. L-1.The detection limit was 6×10-9 mol. L-1.The results showed good reproducibility and stability
关键词POLYANILINE CARBON ACID COMPOSITE FIBERS IONS mesoporous carbon copper determination electrodes
收录类别CSCD
语种英语
资助项目[National Science Foundation of China]
CSCD记录号CSCD:4064776
引用统计
被引频次:1[CSCD]   [CSCD记录]
文献类型期刊论文
条目标识符http://ir.imr.ac.cn/handle/321006/146829
专题中国科学院金属研究所
作者单位中国科学院金属研究所
推荐引用方式
GB/T 7714
Guo Zhuo,Guo Tong,Zhao ChangLi,et al. Preparation of Ordered Mesoporous Carbon/Polyaniline Electrodes and as Electrochemical Sensors for Cu2+[J]. CHINESE JOURNAL OF INORGANIC CHEMISTRY,2010,26(11):1927-1933.
APA Guo Zhuo,Guo Tong,Zhao ChangLi,Gao YunPeng,&Li Sha.(2010).Preparation of Ordered Mesoporous Carbon/Polyaniline Electrodes and as Electrochemical Sensors for Cu2+.CHINESE JOURNAL OF INORGANIC CHEMISTRY,26(11),1927-1933.
MLA Guo Zhuo,et al."Preparation of Ordered Mesoporous Carbon/Polyaniline Electrodes and as Electrochemical Sensors for Cu2+".CHINESE JOURNAL OF INORGANIC CHEMISTRY 26.11(2010):1927-1933.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Guo Zhuo]的文章
[Guo Tong]的文章
[Zhao ChangLi]的文章
百度学术
百度学术中相似的文章
[Guo Zhuo]的文章
[Guo Tong]的文章
[Zhao ChangLi]的文章
必应学术
必应学术中相似的文章
[Guo Zhuo]的文章
[Guo Tong]的文章
[Zhao ChangLi]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。