IMR OpenIR
Magnetic Resonance Three-dimensional Cube Technique in the Measurement of Piglet Femoral Anteversion
其他题名Magnetic Resonance Three-dimensional Cube Technique in the Measurement of Piglet Femoral Anteversion
Sun DongMei; Pan ShiNong; Wang EnBo; Zheng LiQiang; Guo WenLi; Fu XiHu
2016
发表期刊Chinese Medical Journal
ISSN0366-6999
卷号129期号:13页码:1584-1591
摘要Background: The accurate measurement of the femoral anteversion (FA) angle is always a topic of much debate in the orthopedic surgery and radiology research. We aimed to explore a new FA measurement method to acquire accurate results without radiation damage using piglet model. Methods: A total of thirty piglets were assigned to two groups based on the age. Bilateral femora were imaged with 3.0-T magnetic resonance (MR) and 64-slice computed tomography (CT) examinations on all piglets. FA was measured on MR-three-dimensional (3D) postprocessing software with a four-step method: initial validation of the femoral condylar axis, validation of the condylar plane, validation of the femoral neck axis, and line-plane angle measurement of FA. After MR and CT examinations, all piglets were sacrificed and their degree of FA was measured using their excised, dried femora. MR, CT, and dried-femur measurement results were analyzed statistically; MR and CT measurements were compared for accuracy against each other and against the gold standard dried femur measurement. Results: In both groups, the mean FA value measured by MR was lower than that measured by CT. A statistically significant difference was observed between CT- and dried-femur measurements but not between MR- and dried-femur measurements. A higher correlation (0.783 vs. 0.408) and a higher consistency (0.863 vs. 0.578) with dried-femur measurement results were seen for MR measurements than CT measurements in the 1-week age group. However, in the 8-week age group, similar correlations (0.707 vs. 0.669) and consistencies (0.864 vs. 0.821) were observed. Conclusions: Noninvasive MR-3D-Cube reconstruction was able to accurately measure FA in piglets. Particularly in the 1-week age group with a larger proportion of cartilaginous structures, the correlation and consistency between MR- and dried-femur measurement results were higher than those between CT- and dried-femur measurements, suggesting that MR may be a new useful examination tool for FA-related diseases in children.
其他摘要Background: The accurate measurement of the femoral anteversion (FA) angle is always a topic of much debate in the orthopedic surgery and radiology research. We aimed to explore a new FA measurement method to acquire accurate results without radiation damage using piglet model. Methods: A total of thirty piglets were assigned to two groups based on the age. Bilateral femora were imaged with 3.0-T magnetic resonance (MR) and 64-slice computed tomography (CT) examinations on all piglets. FA was measured on MR-three-dimensional (3D) postprocessing software with a four-step method: initial validation of the femoral condylar axis, validation of the condylar plane, validation of the femoral neck axis, and line-plane angle measurement of FA. After MR and CT examinations, all piglets were sacrificed and their degree of FA was measured using their excised, dried femora. MR, CT, and dried-femur measurement results were analyzed statistically; MR and CT measurements were compared for accuracy against each other and against the gold standard dried femur measurement. Results: In both groups, the mean FA value measured by MR was lower than that measured by CT. A statistically significant difference was observed between CT- and dried-femur measurements but not between MR- and dried-femur measurements. A higher correlation (0.783 vs. 0.408) and a higher consistency (0.863 vs. 0.578) with dried-femur measurement results were seen for MR measurements than CT measurements in the 1-week age group. However, in the 8-week age group, similar correlations (0.707 vs. 0.669) and consistencies (0.864 vs. 0.821) were observed. Conclusions: Noninvasive MR-3D-Cube reconstruction was able to accurately measure FA in piglets. Particularly in the 1-week age group with a larger proportion of cartilaginous structures, the correlation and consistency between MR- and dried-femur measurement results were higher than those between CT- and dried-femur measurements, suggesting that MR may be a new useful examination tool for FA-related diseases in children.
关键词Femoral Anteversion Medicine R Hip Magnetic Resonance Imaging Piglet Three-dimensional Fast Spin Echo Cube
收录类别CSCD
语种英语
资助项目[National Natural Science Foundation of China] ; [Outstanding Scientific Fund of Shengjing Hospital]
CSCD记录号CSCD:5741651
引用统计
文献类型期刊论文
条目标识符http://ir.imr.ac.cn/handle/321006/147767
专题中国科学院金属研究所
作者单位中国科学院金属研究所
推荐引用方式
GB/T 7714
Sun DongMei,Pan ShiNong,Wang EnBo,et al. Magnetic Resonance Three-dimensional Cube Technique in the Measurement of Piglet Femoral Anteversion[J]. Chinese Medical Journal,2016,129(13):1584-1591.
APA Sun DongMei,Pan ShiNong,Wang EnBo,Zheng LiQiang,Guo WenLi,&Fu XiHu.(2016).Magnetic Resonance Three-dimensional Cube Technique in the Measurement of Piglet Femoral Anteversion.Chinese Medical Journal,129(13),1584-1591.
MLA Sun DongMei,et al."Magnetic Resonance Three-dimensional Cube Technique in the Measurement of Piglet Femoral Anteversion".Chinese Medical Journal 129.13(2016):1584-1591.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Sun DongMei]的文章
[Pan ShiNong]的文章
[Wang EnBo]的文章
百度学术
百度学术中相似的文章
[Sun DongMei]的文章
[Pan ShiNong]的文章
[Wang EnBo]的文章
必应学术
必应学术中相似的文章
[Sun DongMei]的文章
[Pan ShiNong]的文章
[Wang EnBo]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。