IMR OpenIR
3.0-T magnetic resonance imaging in children with brachial plexus birth injury
其他题名3.0-T magnetic resonance imaging in children with brachial plexus birth injury
Pan Shinong1; Tian Lijie1; Liao Wei1; Tian Feng1; Mao Jian1; Wang Fei1; Bai Rongjie2; Li Qi1; Chen Zhian1; Guo Qiyong1
2011
发表期刊NEURAL REGENERATION RESEARCH
ISSN1673-5374
卷号6期号:6页码:474-480
摘要Brachial plexus birth injuries in children are usually diagnosed using 1.5-T magnetic resonance imaging, while the application of high-field magnetic resonance imaging is rarely reported. Therefore, a retrospective comparison of 18 cases of children with brachial plexus injury was performed to investigate the characteristics of 3.0-T magnetic resonance imaging and intraoperative observations. Magnetic resonance examinations in 18 cases of children showed that pseudo-meningocele sensitivity, specificity, accuracy, and positivity rates were 83.3%, 79.6%, 81.1%, and 40.0%, respectively. As for the neuroma and fibrous scar encapsulation, the sensitivity, specificity, accuracy, and positivity rates were 92.9%, 50.0%, 83.3%, and 77.8%, respectively. These results confirm that 3.0-T high-field magnetic resonance imaging can clearly reveal abnormal changes in brachial plexus injury, in which pseudo-meningocele, fibrous scar encapsulation, and neuroma are the characteristic changes of obstetric brachial plexus preganglionic and postganglionic nerve injury.
其他摘要Brachial plexus birth injuries in children are usually diagnosed using 1.5-T magnetic resonance imaging,while the application of high-field magnetic resonance imaging is rarely reported.Therefore,a retrospective comparison of 18 cases of children with brachial plexus injury was performed to investigate the characteristics of 3.0-T magnetic resonance imaging and intraoperative observations.Magnetic resonance examinations in 18 cases of children showed that pseudo-meningocele sensitivity,specificity,accuracy,and positivity rates were 83.3%,79.6%,81.1%,and 40.0%,respectively.As for the neuroma and fibrous scar encapsulation,the sensitivity,specificity,accuracy,and positivity rates were 92.9%,50.0%,83.3%,and 77.8%,respectively.These results confirm that 3.0-T high-field magnetic resonance imaging can clearly reveal abnormal changes in brachial plexus injury,in which pseudo-meningocele,fibrous scar encapsulation,and neuroma are the characteristic changes of obstetric brachial plexus preganglionic and postganglionic nerve injury.
关键词NEUROGRAPHY MYELOGRAPHY INFANTS MRI FEASIBILITY PALSY magnetic resonance brachial plexus children delivery injury neuroimaging
收录类别CSCD
语种英语
CSCD记录号CSCD:4430588
引用统计
文献类型期刊论文
条目标识符http://ir.imr.ac.cn/handle/321006/151160
专题中国科学院金属研究所
作者单位1.中国科学院金属研究所
2.Beijing Jishuitan Hosp, Department Radiol, Beijing 100035, Peoples R China
推荐引用方式
GB/T 7714
Pan Shinong,Tian Lijie,Liao Wei,et al. 3.0-T magnetic resonance imaging in children with brachial plexus birth injury[J]. NEURAL REGENERATION RESEARCH,2011,6(6):474-480.
APA Pan Shinong.,Tian Lijie.,Liao Wei.,Tian Feng.,Mao Jian.,...&Guo Qiyong.(2011).3.0-T magnetic resonance imaging in children with brachial plexus birth injury.NEURAL REGENERATION RESEARCH,6(6),474-480.
MLA Pan Shinong,et al."3.0-T magnetic resonance imaging in children with brachial plexus birth injury".NEURAL REGENERATION RESEARCH 6.6(2011):474-480.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Pan Shinong]的文章
[Tian Lijie]的文章
[Liao Wei]的文章
百度学术
百度学术中相似的文章
[Pan Shinong]的文章
[Tian Lijie]的文章
[Liao Wei]的文章
必应学术
必应学术中相似的文章
[Pan Shinong]的文章
[Tian Lijie]的文章
[Liao Wei]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。