摘要Background Pulmonary thromboembolism (PTE) is a serious disease often leading to disability and death. Percutaneous placement of an inferior vena cava (IVC) filter is an effective method to prevent fatal PTE caused by lower extremity deep venous thrombosis (LEDVT). We developed the ZQL-type retrievable vena cava filter. The aim of this study was to evaluate the safety and effectiveness of the ZQL-type filter for prevention of fatal PTE.
其他摘要Background Pulmonary thromboembolism (PTE) is a serious disease often leading to disability and death. Percutaneous placement of an inferior vena cava (IVC) filter is an effective method to prevent fatal PTE caused by lower extremity deep venous thrombosis (LEDVT). We developed the ZQL-type retrievable vena cava filter. The aim of this study was to evaluate the safety and effectiveness of the ZQL-type filter for prevention of fatal PTE. Methods A total of 144 patients with indications for placement of an IVC filter received insertion of filters via a femoral (n=37) or jugular (n=107) vein approach. Abdominal X-ray and color Doppler ultrasonography of IVC were regularly performed to visualize the position and condition of the IVC filter following filter placement. If thrombi in the lower extremity deep veins were removed within 2 weeks, the filter retrieval procedure was performed after an abdominal radiograph, an inferior vena cavogram and a pulmonary angiography. Otherwise, the filter should be kept permanently in place with regular follow-up inspections. Results One hundred and forty-four filters were implanted at the target sites with a success rate of 98.61% for one-time placement and 100% for two-time placement. Of the 137 patients followed up (follow-up rate, 95.14%), 43 patients had filters retrieved during a period of between 7 and 14 days (median, 12 days) following filter placement. The remaining 94 patients were followed for 7 days to 39 months (median follow-up period, 17 months). No filter migration or tilt, filter fracture or IVC perforation was observed. No obstruction of IVC occurred. No symptomatic PTE developed during the follow-up period. Conclusion The ZQL-type retrievable vena cava filter is a safe and effective device to prevent PTE. This filter possesses a distinctive stent-shape, stable design, high capture efficacy, and is easy to insert and retrieve and thus is suitable for clinical application.
关键词PULMONARY-EMBOLISM G2 FILTER MIGRATION THROMBOSIS THROMBOEMBOLISM pulmonary embolism vena cava filters venous thrombosis
收录类别CSCD
语种英语
资助项目[National Science and Technology Research Program] ; [Liaoning Province Science and Technology Commission]
CSCD记录号CSCD:3591515
引用统计
文献类型期刊论文
条目标识符http://ir.imr.ac.cn/handle/321006/151905
专题中国科学院金属研究所
作者单位1.中国科学院金属研究所
2.Heilongjiang Prov Hosp, Department Peripheral Vasc Dis, Haerbin 150036, Heilongjiang, Peoples R China
推荐引用方式
GB/T 7714
Xu Ke,Zhou Yubin,Wang Ailin,et al. Clinical study of domestic ZQL-type retrievable vena cava filter[J]. CHINESE MEDICAL JOURNAL,2009,122(2):140-144.
APA Xu Ke,Zhou Yubin,Wang Ailin,&Xiao Liang.(2009).Clinical study of domestic ZQL-type retrievable vena cava filter.CHINESE MEDICAL JOURNAL,122(2),140-144.
MLA Xu Ke,et al."Clinical study of domestic ZQL-type retrievable vena cava filter".CHINESE MEDICAL JOURNAL 122.2(2009):140-144.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Xu Ke]的文章
[Zhou Yubin]的文章
[Wang Ailin]的文章
百度学术
百度学术中相似的文章
[Xu Ke]的文章
[Zhou Yubin]的文章
[Wang Ailin]的文章
必应学术
必应学术中相似的文章
[Xu Ke]的文章
[Zhou Yubin]的文章
[Wang Ailin]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。