IMR OpenIR
Corrosion inhibitor performances for carbon dioxide corrosion of N80 steel under static and flowing conditions
X. Jiang; Y. G. Zheng; W. Ke
2005
Source PublicationCorrosion
ISSN0010-9312
Volume61Issue:4Pages:326-334
AbstractInhibition for carbon dioxide (CO2) corrosion of N80 steel by quaternary alkynoxymethyl amine (IMC-80-Q) in 3% sodium chloride (NaCl) solution was investigated under static and flowing conditions using a modified rotating disk apparatus. The effects of flow velocity and concentration of inhibitor on inhibition performance were performed using a weight-loss test, scanning electron microscope (SEM) observation, and electrochemical techniques including electrochemical impedance spectroscopy (EIS), linear polarization resistance, and polarization curves. The results showed that flow velocity had strong effects on the inhibitor performances. Inhibition efficiency (q) and polarization resistance (R) exhibited the peak-value phenomenon at an inhibitor concentration of 150 mg/L when flow velocity was less than 5 m/s, in contrast with the 300 mg/L when flow velocity was higher than 5 m/s. Critical flow velocity in the uninhibited solution was between 4 m/s and 5 m/s.
description.departmentchinese acad sci, met res inst, state key lab corros & protect, shenyang 110016, liaoning prov, peoples r china.;zheng, yg (reprint author), chinese acad sci, met res inst, state key lab corros & protect, 62 wencui rd, shenyang 110016, liaoning prov, peoples r china;ygzheng@imr.ac.cn
KeywordCarbon Dioxide Corrosion Criticalflow Velocity Flow Effect Inhibitor N80 Steel Peak-value Phenomenon Impedance Plane Displays Rotating Cylinder Stability Conditions Steady-state Pipe-flow Electrode Derivatives Thiourea Velocity
URL查看原文
WOS IDWOS:000228235600003
Citation statistics
Cited Times:38[WOS]   [WOS Record]     [Related Records in WOS]
Document Type期刊论文
Identifierhttp://ir.imr.ac.cn/handle/321006/34884
Collection中国科学院金属研究所
Recommended Citation
GB/T 7714
X. Jiang,Y. G. Zheng,W. Ke. Corrosion inhibitor performances for carbon dioxide corrosion of N80 steel under static and flowing conditions[J]. Corrosion,2005,61(4):326-334.
APA X. Jiang,Y. G. Zheng,&W. Ke.(2005).Corrosion inhibitor performances for carbon dioxide corrosion of N80 steel under static and flowing conditions.Corrosion,61(4),326-334.
MLA X. Jiang,et al."Corrosion inhibitor performances for carbon dioxide corrosion of N80 steel under static and flowing conditions".Corrosion 61.4(2005):326-334.
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[X. Jiang]'s Articles
[Y. G. Zheng]'s Articles
[W. Ke]'s Articles
Baidu academic
Similar articles in Baidu academic
[X. Jiang]'s Articles
[Y. G. Zheng]'s Articles
[W. Ke]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[X. Jiang]'s Articles
[Y. G. Zheng]'s Articles
[W. Ke]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.