IMR OpenIR
Determination of europium (III) by graphite furnace atomic absorption spectrometry with preconcentration by 2-thenoyl trifluoroacetone phenanthrolene modified electrode
H. B. He; W. J. Zhang; G. Z. Ma; H. X. Shen
2001
Source PublicationChinese Journal of Analytical Chemistry
ISSN0253-3820
Volume29Issue:10Pages:1125-1128
AbstractA turgsten filament electrode decorated with a mixture of 2-Thenoyl trifluoracetone (HTTA) and phenanthrolene (phen) were used for preconcentration of europium in (CH2)(6)N-4-HCl buffer, then the electrode was put into a pyrolysis coated graphite cup( PGC) for direct atomization and measurement. The linearity range was found from 0.29 x 10(-8) to 5.9 x 10(-8) mol/L. The relative standard deviation(RSD) was 5.26% and the detection limit (C-L) was 5.9 x 10(-10) mol/L, which was 63.5% to that of HTTA modified electrode and 100-fold lower than reported value determined by pyrolysis coated graphite tube (PGT). This method is more sensitive and selective because ternary minced ligand complex was formed when using two kinds of reagents with suitable ratio. Some common metal ions including aluminum and iron were tolerated, and the interference of rare earth metals was reduced notably.
description.departmentshenyang inst technol, dept basic courses, shenyang 110016, peoples r china. chinese acad sci, inst met res, shenyang 110016, peoples r china. nankai univ, dept chem, tianjin 300071, peoples r china.;he, hb (reprint author), shenyang inst technol, dept basic courses, shenyang 110016, peoples r china
KeywordMixed Ligands Preconcentration Atomic Absorption Spectrometry Europium
URL查看原文
WOS IDWOS:000171887300003
Citation statistics
Cited Times:7[WOS]   [WOS Record]     [Related Records in WOS]
Document Type期刊论文
Identifierhttp://ir.imr.ac.cn/handle/321006/36666
Collection中国科学院金属研究所
Recommended Citation
GB/T 7714
H. B. He,W. J. Zhang,G. Z. Ma,et al. Determination of europium (III) by graphite furnace atomic absorption spectrometry with preconcentration by 2-thenoyl trifluoroacetone phenanthrolene modified electrode[J]. Chinese Journal of Analytical Chemistry,2001,29(10):1125-1128.
APA H. B. He,W. J. Zhang,G. Z. Ma,&H. X. Shen.(2001).Determination of europium (III) by graphite furnace atomic absorption spectrometry with preconcentration by 2-thenoyl trifluoroacetone phenanthrolene modified electrode.Chinese Journal of Analytical Chemistry,29(10),1125-1128.
MLA H. B. He,et al."Determination of europium (III) by graphite furnace atomic absorption spectrometry with preconcentration by 2-thenoyl trifluoroacetone phenanthrolene modified electrode".Chinese Journal of Analytical Chemistry 29.10(2001):1125-1128.
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[H. B. He]'s Articles
[W. J. Zhang]'s Articles
[G. Z. Ma]'s Articles
Baidu academic
Similar articles in Baidu academic
[H. B. He]'s Articles
[W. J. Zhang]'s Articles
[G. Z. Ma]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[H. B. He]'s Articles
[W. J. Zhang]'s Articles
[G. Z. Ma]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.