Determination of europium (III) by graphite furnace atomic absorption spectrometry with preconcentration by 2-thenoyl trifluoroacetone phenanthrolene modified electrode | |
H. B. He; W. J. Zhang; G. Z. Ma; H. X. Shen | |
2001 | |
Source Publication | Chinese Journal of Analytical Chemistry
![]() |
ISSN | 0253-3820 |
Volume | 29Issue:10Pages:1125-1128 |
Abstract | A turgsten filament electrode decorated with a mixture of 2-Thenoyl trifluoracetone (HTTA) and phenanthrolene (phen) were used for preconcentration of europium in (CH2)(6)N-4-HCl buffer, then the electrode was put into a pyrolysis coated graphite cup( PGC) for direct atomization and measurement. The linearity range was found from 0.29 x 10(-8) to 5.9 x 10(-8) mol/L. The relative standard deviation(RSD) was 5.26% and the detection limit (C-L) was 5.9 x 10(-10) mol/L, which was 63.5% to that of HTTA modified electrode and 100-fold lower than reported value determined by pyrolysis coated graphite tube (PGT). This method is more sensitive and selective because ternary minced ligand complex was formed when using two kinds of reagents with suitable ratio. Some common metal ions including aluminum and iron were tolerated, and the interference of rare earth metals was reduced notably. |
description.department | shenyang inst technol, dept basic courses, shenyang 110016, peoples r china. chinese acad sci, inst met res, shenyang 110016, peoples r china. nankai univ, dept chem, tianjin 300071, peoples r china.;he, hb (reprint author), shenyang inst technol, dept basic courses, shenyang 110016, peoples r china |
Keyword | Mixed Ligands Preconcentration Atomic Absorption Spectrometry Europium |
URL | 查看原文 |
WOS ID | WOS:000171887300003 |
Citation statistics | |
Document Type | 期刊论文 |
Identifier | http://ir.imr.ac.cn/handle/321006/36666 |
Collection | 中国科学院金属研究所 |
Recommended Citation GB/T 7714 | H. B. He,W. J. Zhang,G. Z. Ma,et al. Determination of europium (III) by graphite furnace atomic absorption spectrometry with preconcentration by 2-thenoyl trifluoroacetone phenanthrolene modified electrode[J]. Chinese Journal of Analytical Chemistry,2001,29(10):1125-1128. |
APA | H. B. He,W. J. Zhang,G. Z. Ma,&H. X. Shen.(2001).Determination of europium (III) by graphite furnace atomic absorption spectrometry with preconcentration by 2-thenoyl trifluoroacetone phenanthrolene modified electrode.Chinese Journal of Analytical Chemistry,29(10),1125-1128. |
MLA | H. B. He,et al."Determination of europium (III) by graphite furnace atomic absorption spectrometry with preconcentration by 2-thenoyl trifluoroacetone phenanthrolene modified electrode".Chinese Journal of Analytical Chemistry 29.10(2001):1125-1128. |
Files in This Item: | There are no files associated with this item. |
Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.
Edit Comment