IMR OpenIR
The influence of anodic current on surface and bulk deformation at the crack tip of pure copper in 3.5% NaC1 solution
X. Wei; J. Li; X. Zhou; W. Ke
1996
发表期刊Corrosion Science
ISSN0010-938X
卷号38期号:6页码:989-998
摘要The speckle-interferometry technique (SPI) was used to investigate the influence of anodic current on bulk deformation in the plastic zone at crack tip of corrosion Fatigue by comparing the crack tip opening displacements of pure copper specimens in air and in 3.5% NaCl solution. In order to distinguish the different influences of anodic current on the bulk deformation and the surface deformation al crack tip, comparative analyses have been made by measuring the surface strain distributions near crack tip. After applying anodic current, both the plastic zone size and the strain on the surface ahead of crack tip increased significantly. The results indicated that the anodic current has no obvious influence on the deformation of internal material in the plastic zone at crack tip: anodic dissolution can release surface strain hardening and enhance the crack tip surface deformation but it cannot influence the mechanical behavior of internal material in the crack tip plastic zone directly. Copyright (C) 1996 Published by Elsevier Science Ltd.
部门归属wei, x (reprint author), chinese acad sci,state key lab corros & protect,inst corros & protect met,shenyang 110015,peoples r china
关键词Copper Polarization Corrosion Fatigue Displacement
URL查看原文
WOS记录号WOS:A1996UW37100012
引用统计
被引频次:10[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.imr.ac.cn/handle/321006/38440
专题中国科学院金属研究所
推荐引用方式
GB/T 7714
X. Wei,J. Li,X. Zhou,et al. The influence of anodic current on surface and bulk deformation at the crack tip of pure copper in 3.5% NaC1 solution[J]. Corrosion Science,1996,38(6):989-998.
APA X. Wei,J. Li,X. Zhou,&W. Ke.(1996).The influence of anodic current on surface and bulk deformation at the crack tip of pure copper in 3.5% NaC1 solution.Corrosion Science,38(6),989-998.
MLA X. Wei,et al."The influence of anodic current on surface and bulk deformation at the crack tip of pure copper in 3.5% NaC1 solution".Corrosion Science 38.6(1996):989-998.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[X. Wei]的文章
[J. Li]的文章
[X. Zhou]的文章
百度学术
百度学术中相似的文章
[X. Wei]的文章
[J. Li]的文章
[X. Zhou]的文章
必应学术
必应学术中相似的文章
[X. Wei]的文章
[J. Li]的文章
[X. Zhou]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。