Evaluation of aged duplex stainless steel UNS S32750 susceptibility to intergranular corrosion by optimized double loop electrochemical potentiokinetic reactivation method | |
J. F. Hong; D. Han; H. Tan; J. Li; Y. M. Jiang | |
2013 | |
发表期刊 | Corrosion Science
![]() |
ISSN | 0010-938X |
卷号 | 68页码:249-255 |
摘要 | Optimized double loop electrochemical potentiokinetic reactivation (DL-EPR) in combination with microstructure observation were successfully applied to study the sensitization of super duplex stainless steel UNS S32750 aged at 900 degrees C for different duration to intergranular corrosion (IGC). The results indicated that the degree of sensitization increased gradually with the aging time increased from 10 min to 4 h due to the sigma phase precipitation, and I-r:I-a value reached the maximum value of 17.1%. However, further increasing aging time slightly decreased the sensitization due to the healing effect incurred by the diffusion of chromium from adjacent grains to chromium-depleted zone. (C) 2012 Elsevier Ltd. All rights reserved. |
部门归属 | [hong, jufeng ; han, dong ; tan, hua ; li, jin ; jiang, yiming] fudan univ, dept mat sci, shanghai 200433, peoples r china. [tan, hua] state nucl power plant serv co, shanghai, peoples r china. [li, jin] chinese acad sci, inst met res, beijing 100864, peoples r china. ; jiang, ym (reprint author), fudan univ, dept mat sci, shanghai 200433, peoples r china. ; ymjiang@fudan.edu.cn |
关键词 | Stainless Steel Sem Intergranular Corrosion Sensitization Resistance Unss31803 Behavior Environments Tests |
URL | 查看原文 |
语种 | 英语 |
文献类型 | 期刊论文 |
条目标识符 | http://ir.imr.ac.cn/handle/321006/71258 |
专题 | 中国科学院金属研究所 |
推荐引用方式 GB/T 7714 | J. F. Hong,D. Han,H. Tan,et al. Evaluation of aged duplex stainless steel UNS S32750 susceptibility to intergranular corrosion by optimized double loop electrochemical potentiokinetic reactivation method[J]. Corrosion Science,2013,68:249-255. |
APA | J. F. Hong,D. Han,H. Tan,J. Li,&Y. M. Jiang.(2013).Evaluation of aged duplex stainless steel UNS S32750 susceptibility to intergranular corrosion by optimized double loop electrochemical potentiokinetic reactivation method.Corrosion Science,68,249-255. |
MLA | J. F. Hong,et al."Evaluation of aged duplex stainless steel UNS S32750 susceptibility to intergranular corrosion by optimized double loop electrochemical potentiokinetic reactivation method".Corrosion Science 68(2013):249-255. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论