AbstractThe effects of double shielded TIG (tungsten inert gas) torch's structural parameters, including the flow rate ratio between the inner and outer layers of gas and the extended length of the electrode (abbreviated as ELE in this work), on the fusion zone profile have been investigated for 0Cr13Ni5Mo martensitic stainless steel. Results show that the double shielded TIG process yields relatively high penetration of the weld pool in a broad range of the structural parameters. ELE over 3 mm is too large and causes adverse reactions on the protection of electrode. The outer gas with relatively high flow rate or the outer layer with high oxygen content is conducive to the oxygen dissolved into the arc, which results in the oxidation of the weld pool surface and the electrode tip. The double shielded TIG welded metal was tested and presented good impact property.
description.department[li, dongjie ; lu, shanping ; li, dianzhong ; li, yiyi] chinese acad sci, inst met res, shenyang natl lab mat sci, shenyang 110016, peoples r china. ; lu, sp (reprint author), chinese acad sci, inst met res, shenyang natl lab mat sci, shenyang 110016, peoples r china. ; shplu@imr.ac.cn
KeywordStructural Parameters Flow Rate Electrode Extended Length Impact Energy Weld Shape Deep Penetration Gas Protection Fluxes Metal
URL查看原文
Language英语
Document Type期刊论文
Identifierhttp://ir.imr.ac.cn/handle/321006/73263
Collection中国科学院金属研究所
Recommended Citation
GB/T 7714
D. J. Li,S. P. Lu,D. Z. Li,et al. Effect of Structural Parameters of Double Shielded TIG Torch on the Fusion Zone Profile for 0Cr13Ni5Mo Martensitic Stainless Steel[J]. Journal of Materials Science & Technology,2014,30(9):922-927.
APA D. J. Li,S. P. Lu,D. Z. Li,&Y. Y. Li.(2014).Effect of Structural Parameters of Double Shielded TIG Torch on the Fusion Zone Profile for 0Cr13Ni5Mo Martensitic Stainless Steel.Journal of Materials Science & Technology,30(9),922-927.
MLA D. J. Li,et al."Effect of Structural Parameters of Double Shielded TIG Torch on the Fusion Zone Profile for 0Cr13Ni5Mo Martensitic Stainless Steel".Journal of Materials Science & Technology 30.9(2014):922-927.
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[D. J. Li]'s Articles
[S. P. Lu]'s Articles
[D. Z. Li]'s Articles
Baidu academic
Similar articles in Baidu academic
[D. J. Li]'s Articles
[S. P. Lu]'s Articles
[D. Z. Li]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[D. J. Li]'s Articles
[S. P. Lu]'s Articles
[D. Z. Li]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.