IMR OpenIR
Hybrid diamond/graphite films as electrodes for anodic stripping voltammetry of trace Ag+ and Cu2+
Guo, Yuning; Huang, Nan; Yang, Bing; Wang, Chun; Zhuang, Hao; Tian, Qingquan; Zhai, Zhaofeng; Liu, Lusheng; Jiang, Xin; Jiang, X (reprint author), Chinese Acad Sci, Shenyang Natl Lab Mat Sci, Inst Met Res, Wenhua Rd 72, Shenyang 110016, Peoples R China.
2016-08-01
发表期刊SENSORS AND ACTUATORS B-CHEMICAL
ISSN0925-4005
卷号231页码:194-202
摘要Hybrid diamond/graphite nanostructures were synthesized in CH4/H-2 mixture gas using microwave plasma enhanced chemical vapor deposition (MPCVD) at a power of 10 kW. The microstructure and the composition of the films were characterized by scanning electron microscope (SEM), transmission electron microscope (TEM), Raman spectroscopy and X-ray diffraction (XRD). The as-deposited diamond films at high methane level in hydrogen plasma show good conductivity and excellent electrochemical activity, owing to the co-existence of diamond and graphite phases in the films. The largest electrochemical potential window of the hybrid diamond/graphite films is 3.1 V, which is comparable with the B-doped diamond. The films exhibit quasi-reversible, mass controlled electrode reactions in both aqueous and organic solutions. In the application of trace heavy metal ion detection, the hybrid diamond/graphite electrodes present low background currents and detection limits (S/N >= 3): similar to 1.5 mu A/cm(2) and 5.8 ppb for Ag+, similar to 4.7 mu A/cm(2) and 5.6 ppb for Cu2+. The diamond/graphite electrodes also possess good linearity over a wide concentration range from 10 ppb to 1 ppm. In addition, the simultaneous determination of silver and copper ions was also successful. The good recovery values for the analysis of the tap water samples with standard addition method demonstrate the accuracy of the hybrid diamond/graphite electrodes. Hence, the hybrid diamond/graphite films are promising for electrochemical applications such as trace heavy metal ions detection because of its wide potential window, lower background current and high sensitivity. (C) 2016 Published by Elsevier B.V.
部门归属[guo, yuning ; huang, nan ; yang, bing ; wang, chun ; tian, qingquan ; zhai, zhaofeng ; liu, lusheng ; jiang, xin] chinese acad sci, shenyang natl lab mat sci, inst met res, wenhua rd 72, shenyang 110016, peoples r china ; [zhuang, hao ; jiang, xin] univ siegen, inst mat engn, paul bonatz str 9-11, d-57076 siegen, germany
关键词Diamond Graphite Electrochemical Heavy Metal Ions Anodic Stripping Voltammetry
学科领域Chemistry ; Electrochemistry ; Instruments & Instrumentation
资助者National Natural Science Foundation of China [51202257]; Innovation Foundation of Institute of Metal Research, Chinese Academy of Sciences [SCJJ-2013-PY-06]
收录类别sci
语种英语
WOS记录号WOS:000374330900023
引用统计
被引频次:32[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.imr.ac.cn/handle/321006/75786
专题中国科学院金属研究所
通讯作者Jiang, X (reprint author), Chinese Acad Sci, Shenyang Natl Lab Mat Sci, Inst Met Res, Wenhua Rd 72, Shenyang 110016, Peoples R China.
推荐引用方式
GB/T 7714
Guo, Yuning,Huang, Nan,Yang, Bing,et al. Hybrid diamond/graphite films as electrodes for anodic stripping voltammetry of trace Ag+ and Cu2+[J]. SENSORS AND ACTUATORS B-CHEMICAL,2016,231:194-202.
APA Guo, Yuning.,Huang, Nan.,Yang, Bing.,Wang, Chun.,Zhuang, Hao.,...&Jiang, X .(2016).Hybrid diamond/graphite films as electrodes for anodic stripping voltammetry of trace Ag+ and Cu2+.SENSORS AND ACTUATORS B-CHEMICAL,231,194-202.
MLA Guo, Yuning,et al."Hybrid diamond/graphite films as electrodes for anodic stripping voltammetry of trace Ag+ and Cu2+".SENSORS AND ACTUATORS B-CHEMICAL 231(2016):194-202.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Guo, Yuning]的文章
[Huang, Nan]的文章
[Yang, Bing]的文章
百度学术
百度学术中相似的文章
[Guo, Yuning]的文章
[Huang, Nan]的文章
[Yang, Bing]的文章
必应学术
必应学术中相似的文章
[Guo, Yuning]的文章
[Huang, Nan]的文章
[Yang, Bing]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。