The relationship between the measured signals (hydrogen [H] permeating rate) of an electrochemical H sensor and the strength/embrittlement of plain carbon steel in acid solution as defined by slow strain rate tensile tests and scanning electron microscopy was studied. Critical parameters and criteria for hydrogen-induced cracking (HIC) reported may be useful in software design of an electrochemical probe for inspecting and monitoring the HIC susceptibility of steel in pickling.
CHINESE ACAD SCI,INST CORROS & PROTECT MET,CORROS SCI LAB,SHENYANG 110015,PEOPLES R CHINA
推荐引用方式 GB/T 7714
CHENG, YF,DU, YL. DESIGN OF AN ELECTROCHEMICAL PROBE FOR MONITORING SUSCEPTIBILITY OF STEEL IN PICKLING TO HYDROGEN-INDUCED CRACKING[J]. CORROSION,1993,49(9):776-781.
APA
CHENG, YF,&DU, YL.(1993).DESIGN OF AN ELECTROCHEMICAL PROBE FOR MONITORING SUSCEPTIBILITY OF STEEL IN PICKLING TO HYDROGEN-INDUCED CRACKING.CORROSION,49(9),776-781.
MLA
CHENG, YF,et al."DESIGN OF AN ELECTROCHEMICAL PROBE FOR MONITORING SUSCEPTIBILITY OF STEEL IN PICKLING TO HYDROGEN-INDUCED CRACKING".CORROSION 49.9(1993):776-781.