Improvement of porous electro-conductive membrane preparation and its application in sample injection pre-concentration in capillary electrophoresis of proteins | |
其他题名 | Improvement of Porous Electro-conductive Membrane Preparation and Its Application in Sample Injection Pre-concentration in Capillary Electrophoresis of Proteins |
Wang YaRong; Li JingJing; Wu ZhiYong; Fan JunGang; Fang Fang | |
2008 | |
发表期刊 | CHINESE JOURNAL OF ANALYTICAL CHEMISTRY
![]() |
ISSN | 0253-3820 |
卷号 | 36期号:7页码:879-884 |
摘要 | The success rate of porous conductive membrane preparation on fused silica capillary was greatly improved by control of voltage bias and electroosmosis effect. Basic buffer media was filled into the column, and a direct curvent voltage was applied between the capillary inlet and the etching reservoir during the etching process. The etching was stopped due to electroosmosis effect when electro-conductivity of the etching membrane occurred, and over etching was automatically avoided. The conductive membrane prepared was successfully used in on-line sample electro injection pre-concentration and capillary electrophoresis separation of model proteins of lysozyme and bovine serum albumin in 0.05 mol/L pH 2.50 Tris-H, PO, with 2% - 4% dextran, and a concentration factor close to the theoretical value was obtained. The difference of concentration factors for basic and acidic proteins was discussed. Detection limits for the model proteins were decreased to 1 x 10(-11) mol/L with a routinely used photometric detector (214 nm wavelegnth) by electro-injection pre-concentration for 30 min. |
关键词 | ZONE-ELECTROPHORESIS ELECTROKINETIC CHROMATOGRAPHY SENSITIVITY ENHANCEMENT ETCHED JOINT STACKING SYSTEM SEPARATION INTERFACE PEPTIDES capillary electrophoresis porous conductive membrane injection pre-concentration lysozyme bovine serum albumin ultraviolet detection |
收录类别 | CSCD |
语种 | 英语 |
CSCD记录号 | CSCD:3333224 |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.imr.ac.cn/handle/321006/146268 |
专题 | 中国科学院金属研究所 |
作者单位 | 中国科学院金属研究所 |
推荐引用方式 GB/T 7714 | Wang YaRong,Li JingJing,Wu ZhiYong,et al. Improvement of porous electro-conductive membrane preparation and its application in sample injection pre-concentration in capillary electrophoresis of proteins[J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,2008,36(7):879-884. |
APA | Wang YaRong,Li JingJing,Wu ZhiYong,Fan JunGang,&Fang Fang.(2008).Improvement of porous electro-conductive membrane preparation and its application in sample injection pre-concentration in capillary electrophoresis of proteins.CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,36(7),879-884. |
MLA | Wang YaRong,et al."Improvement of porous electro-conductive membrane preparation and its application in sample injection pre-concentration in capillary electrophoresis of proteins".CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 36.7(2008):879-884. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论