Compatibility of rubber stoppers for recombinant antitumor-antivirus protein injection by gas chromatography-mass spectrometry | |
其他题名 | Compatibility of rubber stoppers for recombinant antitumor-antivirus protein injection by gas chromatography-mass spectrometry |
Zhaorui Meng1; Xun Gao1; Haifeng Yu2; Lan Zhang2; Xiangyong Yu3; Longshan Zhao1 | |
2019 | |
发表期刊 | 药物分析学报:英文版
![]() |
ISSN | 2095-1779 |
卷号 | 9.0期号:003页码:178-184 |
摘要 | A simple, rapid, and sensitive gas chromatography-mass spectrometry (GC-MS) method was developed and validated for the simultaneous determination of two fatty acids, methyl hexadecanoate (MH) and methyl stearate (MS), to allow the evaluation of packaging-drug compatibility. The two migrants were quantified in selective ion-monitoring (SIM) mode, with limits of detection (LOD) of 0.0030 μg/mL and 0.0121 μg/mL. Linear calibration curves for MH and MS were obtained in the concentration ranges of 0.1011–5.0570 μg/mL and 0.2015–10.0740 μg/mL, respectively. The developed method was successfully applied to estimate the safety of the injection of recombinant antitumor-antivirus protein (RAAP). The results showed that the possible maximum daily intake was 3.0 ng and 12.1 ng for MH and MS, respectively. As these values were both below the permitted daily exposure, the migrants can be considered as having low safety risk and do not affect the quality of the injection. |
其他摘要 | A simple, rapid, and sensitive gas chromatography-mass spectrometry (GC-MS) method was developed and validated for the simultaneous determination of two fatty acids, methyl hexadecanoate (MH) and methyl stearate (MS), to allow the evaluation of packaging-drug compatibility. The two migrants were quantified in selective ion-monitoring (SIM) mode, with limits of detection (LOD) of 0.0030 μg/mL and 0.0121 μg/mL. Linear calibration curves for MH and MS were obtained in the concentration ranges of 0.1011–5.0570 μg/mL and 0.2015–10.0740 μg/mL, respectively. The developed method was successfully applied to estimate the safety of the injection of recombinant antitumor-antivirus protein (RAAP). The results showed that the possible maximum daily intake was 3.0 ng and 12.1 ng for MH and MS, respectively. As these values were both below the permitted daily exposure, the migrants can be considered as having low safety risk and do not affect the quality of the injection. |
关键词 | Compatibility Rubber stoppers Injection Fatty acids GC-MS |
收录类别 | CSCD |
语种 | 中文 |
CSCD记录号 | CSCD:6521749 |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.imr.ac.cn/handle/321006/147563 |
专题 | 中国科学院金属研究所 |
作者单位 | 1.沈阳药科大学 2.Anshan Institute for Food and Drug Control, Anshan 3.中国科学院金属研究所 |
推荐引用方式 GB/T 7714 | Zhaorui Meng,Xun Gao,Haifeng Yu,et al. Compatibility of rubber stoppers for recombinant antitumor-antivirus protein injection by gas chromatography-mass spectrometry[J]. 药物分析学报:英文版,2019,9.0(003):178-184. |
APA | Zhaorui Meng,Xun Gao,Haifeng Yu,Lan Zhang,Xiangyong Yu,&Longshan Zhao.(2019).Compatibility of rubber stoppers for recombinant antitumor-antivirus protein injection by gas chromatography-mass spectrometry.药物分析学报:英文版,9.0(003),178-184. |
MLA | Zhaorui Meng,et al."Compatibility of rubber stoppers for recombinant antitumor-antivirus protein injection by gas chromatography-mass spectrometry".药物分析学报:英文版 9.0.003(2019):178-184. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论