摘要A simple, rapid, and sensitive gas chromatography-mass spectrometry (GC-MS) method was developed and validated for the simultaneous determination of two fatty acids, methyl hexadecanoate (MH) and methyl stearate (MS), to allow the evaluation of packaging-drug compatibility. The two migrants were quantified in selective ion-monitoring (SIM) mode, with limits of detection (LOD) of 0.0030 μg/mL and 0.0121 μg/mL. Linear calibration curves for MH and MS were obtained in the concentration ranges of 0.1011–5.0570 μg/mL and 0.2015–10.0740 μg/mL, respectively. The developed method was successfully applied to estimate the safety of the injection of recombinant antitumor-antivirus protein (RAAP). The results showed that the possible maximum daily intake was 3.0 ng and 12.1 ng for MH and MS, respectively. As these values were both below the permitted daily exposure, the migrants can be considered as having low safety risk and do not affect the quality of the injection.
其他摘要A simple, rapid, and sensitive gas chromatography-mass spectrometry (GC-MS) method was developed and validated for the simultaneous determination of two fatty acids, methyl hexadecanoate (MH) and methyl stearate (MS), to allow the evaluation of packaging-drug compatibility. The two migrants were quantified in selective ion-monitoring (SIM) mode, with limits of detection (LOD) of 0.0030 μg/mL and 0.0121 μg/mL. Linear calibration curves for MH and MS were obtained in the concentration ranges of 0.1011–5.0570 μg/mL and 0.2015–10.0740 μg/mL, respectively. The developed method was successfully applied to estimate the safety of the injection of recombinant antitumor-antivirus protein (RAAP). The results showed that the possible maximum daily intake was 3.0 ng and 12.1 ng for MH and MS, respectively. As these values were both below the permitted daily exposure, the migrants can be considered as having low safety risk and do not affect the quality of the injection.
关键词Compatibility Rubber stoppers Injection Fatty acids GC-MS
收录类别CSCD
语种中文
CSCD记录号CSCD:6521749
引用统计
被引频次:1[CSCD]   [CSCD记录]
文献类型期刊论文
条目标识符http://ir.imr.ac.cn/handle/321006/147563
专题中国科学院金属研究所
作者单位1.沈阳药科大学
2.Anshan Institute for Food and Drug Control, Anshan
3.中国科学院金属研究所
推荐引用方式
GB/T 7714
Zhaorui Meng,Xun Gao,Haifeng Yu,et al. Compatibility of rubber stoppers for recombinant antitumor-antivirus protein injection by gas chromatography-mass spectrometry[J]. 药物分析学报:英文版,2019,9.0(003):178-184.
APA Zhaorui Meng,Xun Gao,Haifeng Yu,Lan Zhang,Xiangyong Yu,&Longshan Zhao.(2019).Compatibility of rubber stoppers for recombinant antitumor-antivirus protein injection by gas chromatography-mass spectrometry.药物分析学报:英文版,9.0(003),178-184.
MLA Zhaorui Meng,et al."Compatibility of rubber stoppers for recombinant antitumor-antivirus protein injection by gas chromatography-mass spectrometry".药物分析学报:英文版 9.0.003(2019):178-184.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Zhaorui Meng]的文章
[Xun Gao]的文章
[Haifeng Yu]的文章
百度学术
百度学术中相似的文章
[Zhaorui Meng]的文章
[Xun Gao]的文章
[Haifeng Yu]的文章
必应学术
必应学术中相似的文章
[Zhaorui Meng]的文章
[Xun Gao]的文章
[Haifeng Yu]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。