AbstractBackground As a new electroencephalogram (EEG) signal processing technique for monitoring the depth of anesthesia, entropy consists of two indices: reaction entropy (RE) and state entropy (SE). Our study compared entropy with classical bispectral index (BIS) in reduction of myoelectrical interference and noxious stimuli with EEG signals.
Other AbstractBackground As a new electroencephalogram (EEG) signal processing technique for monitoring the depth of anesthesia, entropy consists of two indices: reaction entropy (RE) and state entropy (SE). Our study compared entropy with classical bispectral index (BIS) in reduction of myoelectrical interference and noxious stimuli with EEG signals. Methods Two hundred and eighty patients (ASA I–II, 18–60 years old) undergoing scheduled surgeries from seven medical centers were enrolled. Anesthesia induction was managed with propofol via the target-controlled infusion (TCI) system. The results of BIS, RE, SE, mean arterial pressure (MAP) and heart rate (HR) were recorded before anesthesia induction, at the moment of unconsciousness, before and 2 minutes after administration of muscle relaxant, and before and one and three minutes after the tracheal intubation. Results The values of half maximum effective concentrations (EC50), 5% effective concentrations (EC05) and 95% effective concentrations (EC95) of propofol effect-site concentration at the onset of unconsciousness were 1.2 (1.1–1.3 μg/ml), 2.5 (2.4–2.5 μg/ml) and 3.7 (3.7–3.8 μg/ml), while those of the predicted plasma propofol concentration were 2.8 (2.7–2.9 μg/ml), 3.9 (3.8–3.9 μg/ml) and 4.9 (4.8–5.0 μg/ml), respectively. The values of BIS, SE and RE were 62, 59 and 63 when 50% of patients lost consciousness, and 79, 80, 85 and 42, 37, 44, respectively, when 5% and 95% of patients were unconscious. The values of BIS, RE and SE dropped two minutes after the injection of muscle relaxant, but there were no significant differences between RE and SE. MAP and HR increased visibly, which indicated a reaction to tracheal intubation; the values of BIS, RE and SE, however, did not display any significant changes. Conclusions This large-sample multicentric study confirmed the values of RE and SE as approximating BIS value, at the onset of unconsciousness during propofol TCI anesthesia. After elimination of myoelectrical activation, all values of RE, SE and BIS decreased significantly and the three indices were less sensitive to noxious stimuli than cardiovascular responses.
KeywordSPECTRAL ENTROPY NEUROMUSCULAR BLOCK MUSCLE-RELAXANT FREQUENCY PANCURONIUM PERFORMANCE SEVOFLURANE HALOTHANE PROPOFOL VALUES propofol target-controlled infusion unconsciousness bispectral index entropy dose-response relationship
Indexed ByCSCD
Language英语
CSCD IDCSCD:4498353
Citation statistics
Cited Times:1[CSCD]   [CSCD Record]
Document Type期刊论文
Identifierhttp://ir.imr.ac.cn/handle/321006/150702
Collection中国科学院金属研究所
Affiliation1.Capital Med University, Beijing Chaoyang Hosp, Dept Anesthesiol, Beijing 100020, Peoples R China
2.Chinese Acad Med Sci, Department Anesthesiol, Beijing 100730, Peoples R China Department Anesthesiol
3.Beijing Union Med Coll Hosp, Beijing 100730, Peoples R China
4.Capital Med University, Xuanwu Hosp, Dept Anesthesiol, Beijing 100053, Peoples R China
5.中国科学院金属研究所
6.中国科学院地球环境研究所
7.复旦大学
8.中国科学院广州地球化学研究所
Recommended Citation
GB/T 7714
Gao Jiandong,Zhao Yujie,Xu Chenshi,et al. Evaluation of entropy for monitoring the depth of anesthesia compared with bispectral index: a multicenter clinical trial[J]. CHINESE MEDICAL JOURNAL,2012,125(8):1389-1392.
APA Gao Jiandong.,Zhao Yujie.,Xu Chenshi.,Zhao Jing.,Huang Yuguang.,...&Yue Yun.(2012).Evaluation of entropy for monitoring the depth of anesthesia compared with bispectral index: a multicenter clinical trial.CHINESE MEDICAL JOURNAL,125(8),1389-1392.
MLA Gao Jiandong,et al."Evaluation of entropy for monitoring the depth of anesthesia compared with bispectral index: a multicenter clinical trial".CHINESE MEDICAL JOURNAL 125.8(2012):1389-1392.
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Gao Jiandong]'s Articles
[Zhao Yujie]'s Articles
[Xu Chenshi]'s Articles
Baidu academic
Similar articles in Baidu academic
[Gao Jiandong]'s Articles
[Zhao Yujie]'s Articles
[Xu Chenshi]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Gao Jiandong]'s Articles
[Zhao Yujie]'s Articles
[Xu Chenshi]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.