Application of Temperature Inference Method Based on Soft Sensor Technique to Plate Production Process | |
Alternative Title | Application of Temperature Inference Method Based on Soft Sensor Technique to Plate Production Process |
Ding Jingguo1; Qu Lili2; Hu Xianlei1; Liu Xianghua1 | |
2011 | |
Source Publication | JOURNAL OF IRON AND STEEL RESEARCH INTERNATIONAL
![]() |
ISSN | 1006-706X |
Volume | 18Issue:3Pages:24-27 |
Abstract | There is a certain extent of measuring error for each pyrometer in plate production process, which has a great impact on process control system. A soft sensor technique is used to calculate the confidence interval of measuring temperature data from pyrometers and an inference estimator is designed by partial least square method, then the pyrometer with highest confidence is considered as the reference one, with which inference estimation for measured data on-line of other pyrometers is started and the measuring error is conformed. From actual application it can be found that this method can improve the measuring accuracy by 3%-5%, and has high field application value. |
Other Abstract | There is a certain extent of measuring error for each pyrometer in plate production process,which has a great impact on process control system.A soft sensor technique is used to calculate the confidence interval of measuring temperature data from pyrometers and an inference estimator is designed by partial least square method,then the pyrometer with highest confidence is considered as the reference one,with which inference estimation for measured data on-line of other pyrometers is started and the measuring error is conformed.From actual application it can be found that this method can improve the measuring accuracy by 3%-5%,and has high field application value. |
Keyword | plate mill soft sensor temperature inference partial least square |
Indexed By | CSCD |
Language | 英语 |
Funding Project | [National Natural Science Foundation of China] |
CSCD ID | CSCD:4381693 |
Citation statistics |
Cited Times:1[CSCD]
[CSCD Record]
|
Document Type | 期刊论文 |
Identifier | http://ir.imr.ac.cn/handle/321006/152530 |
Collection | 中国科学院金属研究所 |
Affiliation | 1.东北大学 2.中国科学院金属研究所 |
Recommended Citation GB/T 7714 | Ding Jingguo,Qu Lili,Hu Xianlei,et al. Application of Temperature Inference Method Based on Soft Sensor Technique to Plate Production Process[J]. JOURNAL OF IRON AND STEEL RESEARCH INTERNATIONAL,2011,18(3):24-27. |
APA | Ding Jingguo,Qu Lili,Hu Xianlei,&Liu Xianghua.(2011).Application of Temperature Inference Method Based on Soft Sensor Technique to Plate Production Process.JOURNAL OF IRON AND STEEL RESEARCH INTERNATIONAL,18(3),24-27. |