Multi-wire plaque crushing as a novel technique in treating chronic total occlusions | |
Alternative Title | Multi-wire plaque crushing as a novel technique in treating chronic total occlusions |
Han Yaling; Li Yi; Wang Shouli; Jing Quanmin; Ma Yingyan; Wang Geng; Luan Bo; Wang Bin; Wang Zhulu; Wang Dongmei | |
2008 | |
Source Publication | CHINESE MEDICAL JOURNAL
![]() |
ISSN | 0366-6999 |
Volume | 121Issue:6Pages:518-521 |
Abstract | Background Failure of balloon catheter passing through the occluded segment accounts for 10%-15% of all procedures during percutaneous coronary intervention (PCI) for chronic total occlusion (CTO). We sought to investigate an original technique for facilitating balloon catheter passing by multi-wire plaque crushing. |
Other Abstract | Background Failure of balloon catheter passing through the occluded segment accounts for 10%–15% of all procedures during percutaneous coronary intervention (PCI) for chronic total occlusion (CTO). We sought to investigate an original technique for facilitating balloon catheter passing by multi-wire plaque crushing.Methods Between July 2000 and October 2007, 152 patients with 164 CTO lesions who had failed balloon passing were treated by multi-wire plaque crushing technique. The main process of this technique was to insert 1 or 2 wires along with the original wire located in the true lumen of CTO lesions after balloon failure for plaque crushing and then to withdraw the crushing wires to get an enlarged lumen inside of the occlusion segment, thus facilitating the balloon passing. Results Both overall lesion and technique success rates were 91.5% (150/164). A total of 211 crushing wires were used during PCI, including 1 crushing wire for 117 (71.3%) lesions and 2 crushing wires for 47 (28.7%) lesions. Approximately 57.3% (121/211) of all crushing wires were those already used in the same procedure. Technique failure occurred in 14 lesions (8.5%). Technique failure was due to crushing wires entering false lumen (92.9%, 13/14) and coronary perforation (7.1%, 1/14). Major procedural complications included coronary perforation (1 case) and severe coronary dissection (2 cases), all of which were successfully treated.Conclusions Multi-wire plaque crushing technique is effective in facilitating balloon catheter passing during CTOPCI. It is feasible, economical and relatively safe with a low rate of procedural complications. |
Keyword | OCCLUDED CORONARY-ARTERIES PERCUTANEOUS RECANALIZATION CONSENSUS DOCUMENT ANGIOPLASTY REVASCULARIZATION INTERVENTION CATHETER percutaneous coronary intervention chronic total occlusions multi-wire plaque crushing |
Indexed By | CSCD |
Language | 英语 |
CSCD ID | CSCD:3249031 |
Citation statistics | |
Document Type | 期刊论文 |
Identifier | http://ir.imr.ac.cn/handle/321006/153473 |
Collection | 中国科学院金属研究所 |
Affiliation | 中国科学院金属研究所 |
Recommended Citation GB/T 7714 | Han Yaling,Li Yi,Wang Shouli,et al. Multi-wire plaque crushing as a novel technique in treating chronic total occlusions[J]. CHINESE MEDICAL JOURNAL,2008,121(6):518-521. |
APA | Han Yaling.,Li Yi.,Wang Shouli.,Jing Quanmin.,Ma Yingyan.,...&Wang Dongmei.(2008).Multi-wire plaque crushing as a novel technique in treating chronic total occlusions.CHINESE MEDICAL JOURNAL,121(6),518-521. |
MLA | Han Yaling,et al."Multi-wire plaque crushing as a novel technique in treating chronic total occlusions".CHINESE MEDICAL JOURNAL 121.6(2008):518-521. |
Files in This Item: | There are no files associated with this item. |
Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.
Edit Comment