IMR OpenIR
Influence of Nucleotide-biased Fluorescence Emissions of SYBR Green II on the Result Consistence of Rolling Circle Amplification
Zhang Bin1; Jiang Jiquan1; Yuan Ying1; Guan Yifu1
2019
发表期刊CHEMICAL RESEARCH IN CHINESE UNIVERSITIES
ISSN1005-9040
卷号35期号:6页码:1119-1123
摘要The fluorescence dye SYBR Green II(SG II) has been frequently used in rolling circle amplification(RCA) based analyses of nucleic acids. However, a good amount of inconsistencies have been reported in regards the quality and reproducibility of RCA reactions. To properly examine this experimental issue, here we utilized a series of synthetic oligonucleotides and circular templates to investigate the impact of SG II in RCA reactions. The results indicate that SG II enables a strong fluorescence signal only when complexing with guanosine(G) residue. In RCA reactions, long single-stranded RCA products, enriched with G residues, result in higher fluorescence emission when compared with the addition of other nucleotide residues. These results suggest that the nucleotide composition of the reaction can affect the amplification results and, eventually, can lead to inconsistent fluorescence of the RCA products. This work indicates that particular attention should be given when circular templates are designed for the quantitative analysis of nucleic acids, to further allow the signal reproducibility of RCA-based experiments.
关键词DNA DETECTION QUADRUPLEX IDENTIFICATION STABILITY Rolling circle amplification SYBR Green II Nucleotide-biased Fluorescence emission
收录类别CSCD
语种英语
资助项目[National Natural Science Foundation of China]
CSCD记录号CSCD:6626732
引用统计
文献类型期刊论文
条目标识符http://ir.imr.ac.cn/handle/321006/155543
专题中国科学院金属研究所
作者单位1.中国科学院地质与地球物理研究所
2.中国科学院金属研究所
推荐引用方式
GB/T 7714
Zhang Bin,Jiang Jiquan,Yuan Ying,et al. Influence of Nucleotide-biased Fluorescence Emissions of SYBR Green II on the Result Consistence of Rolling Circle Amplification[J]. CHEMICAL RESEARCH IN CHINESE UNIVERSITIES,2019,35(6):1119-1123.
APA Zhang Bin,Jiang Jiquan,Yuan Ying,&Guan Yifu.(2019).Influence of Nucleotide-biased Fluorescence Emissions of SYBR Green II on the Result Consistence of Rolling Circle Amplification.CHEMICAL RESEARCH IN CHINESE UNIVERSITIES,35(6),1119-1123.
MLA Zhang Bin,et al."Influence of Nucleotide-biased Fluorescence Emissions of SYBR Green II on the Result Consistence of Rolling Circle Amplification".CHEMICAL RESEARCH IN CHINESE UNIVERSITIES 35.6(2019):1119-1123.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Zhang Bin]的文章
[Jiang Jiquan]的文章
[Yuan Ying]的文章
百度学术
百度学术中相似的文章
[Zhang Bin]的文章
[Jiang Jiquan]的文章
[Yuan Ying]的文章
必应学术
必应学术中相似的文章
[Zhang Bin]的文章
[Jiang Jiquan]的文章
[Yuan Ying]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。