Electrochemical DNA biosensor based on conducting polyaniline nanotube array | |
H. X. Chang; Y. Yuan; N. L. Shi; Y. F. Guan | |
2007 | |
发表期刊 | Analytical Chemistry
![]() |
ISSN | 0003-2700 |
卷号 | 79期号:13页码:5111-5115 |
摘要 | Most of the recent developments in ultrasensitive detection of nucleic acid are based on the gold nanoparticles and carbon nanotubes as a medium of signal amplification. Here, we present an ultrasensitive electrochemical nucleic acid biosensor using the conducting polyaniline (PANI) nanotube array as the signal enhancement element. The PANI nanotube array of a highly organized structure was fabricated under a well-controlled nanoscale dimension on the graphite electrode using a thin nano-porous layer as a template, and 21-mer oligonucleotide probes were immobilized on these PANI nanotubes. In comparison with gold nanoparticle- or carbon nanotube-based DNA biosensors, our PANI nanotube array-based DNA biosensor could achieve similar sensitivity without catalytic enhancement, purification, or end-opening processing. The electrochemical results showed that the conducting PANI nanotube array had a signal enhancement capability, allowing the DNA biosensor to readily detect the target oligonucleotide at a concentration as low as 1.0 fM (similar to 300 zmol of target molecules). In addition, this biosensor demonstrated good capability of differentiating the perfect matched target oligonucleotide from one-nucleotide mismatched oligonucleotides even at a concentration of 37.59 fM. This detection specificity indicates that this biosensor could be applied to single-nucleotide polymorphism analysis and single-mutation detection. |
部门归属 | chinese acad sci, inst met res, div mat surface engn, shenyang 110016, peoples r china. chinese acad sci, grad sch, beijing 100080, peoples r china. china med univ, dept biochem & mol biol, shenyang 110001, peoples r china.;chang, hx (reprint author), chinese acad sci, inst met res, div mat surface engn, shenyang 110016, peoples r china;hxchang@imr.ac.cn yfguan55@sina.com |
关键词 | Electrical Detection Nanoparticle Probes Hybridization |
URL | 查看原文 |
WOS记录号 | WOS:000247611600047 |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.imr.ac.cn/handle/321006/33436 |
专题 | 中国科学院金属研究所 |
推荐引用方式 GB/T 7714 | H. X. Chang,Y. Yuan,N. L. Shi,et al. Electrochemical DNA biosensor based on conducting polyaniline nanotube array[J]. Analytical Chemistry,2007,79(13):5111-5115. |
APA | H. X. Chang,Y. Yuan,N. L. Shi,&Y. F. Guan.(2007).Electrochemical DNA biosensor based on conducting polyaniline nanotube array.Analytical Chemistry,79(13),5111-5115. |
MLA | H. X. Chang,et al."Electrochemical DNA biosensor based on conducting polyaniline nanotube array".Analytical Chemistry 79.13(2007):5111-5115. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。