IMR OpenIR
Determination of europium (III) by graphite furnace atomic absorption spectrometry with preconcentration by 2-thenoyl trifluoroacetone phenanthrolene modified electrode
H. B. He; W. J. Zhang; G. Z. Ma; H. X. Shen
2001
发表期刊Chinese Journal of Analytical Chemistry
ISSN0253-3820
卷号29期号:10页码:1125-1128
摘要A turgsten filament electrode decorated with a mixture of 2-Thenoyl trifluoracetone (HTTA) and phenanthrolene (phen) were used for preconcentration of europium in (CH2)(6)N-4-HCl buffer, then the electrode was put into a pyrolysis coated graphite cup( PGC) for direct atomization and measurement. The linearity range was found from 0.29 x 10(-8) to 5.9 x 10(-8) mol/L. The relative standard deviation(RSD) was 5.26% and the detection limit (C-L) was 5.9 x 10(-10) mol/L, which was 63.5% to that of HTTA modified electrode and 100-fold lower than reported value determined by pyrolysis coated graphite tube (PGT). This method is more sensitive and selective because ternary minced ligand complex was formed when using two kinds of reagents with suitable ratio. Some common metal ions including aluminum and iron were tolerated, and the interference of rare earth metals was reduced notably.
部门归属shenyang inst technol, dept basic courses, shenyang 110016, peoples r china. chinese acad sci, inst met res, shenyang 110016, peoples r china. nankai univ, dept chem, tianjin 300071, peoples r china.;he, hb (reprint author), shenyang inst technol, dept basic courses, shenyang 110016, peoples r china
关键词Mixed Ligands Preconcentration Atomic Absorption Spectrometry Europium
URL查看原文
WOS记录号WOS:000171887300003
引用统计
被引频次:7[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.imr.ac.cn/handle/321006/36666
专题中国科学院金属研究所
推荐引用方式
GB/T 7714
H. B. He,W. J. Zhang,G. Z. Ma,et al. Determination of europium (III) by graphite furnace atomic absorption spectrometry with preconcentration by 2-thenoyl trifluoroacetone phenanthrolene modified electrode[J]. Chinese Journal of Analytical Chemistry,2001,29(10):1125-1128.
APA H. B. He,W. J. Zhang,G. Z. Ma,&H. X. Shen.(2001).Determination of europium (III) by graphite furnace atomic absorption spectrometry with preconcentration by 2-thenoyl trifluoroacetone phenanthrolene modified electrode.Chinese Journal of Analytical Chemistry,29(10),1125-1128.
MLA H. B. He,et al."Determination of europium (III) by graphite furnace atomic absorption spectrometry with preconcentration by 2-thenoyl trifluoroacetone phenanthrolene modified electrode".Chinese Journal of Analytical Chemistry 29.10(2001):1125-1128.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[H. B. He]的文章
[W. J. Zhang]的文章
[G. Z. Ma]的文章
百度学术
百度学术中相似的文章
[H. B. He]的文章
[W. J. Zhang]的文章
[G. Z. Ma]的文章
必应学术
必应学术中相似的文章
[H. B. He]的文章
[W. J. Zhang]的文章
[G. Z. Ma]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。